Ninebot ESX Error Code 14
"Throttle Hall is abnormal, please check the Throttle Switch, Dashboard & related Connections"
If your Segway Ninebot ESX(ES1, ES2, ES3, or ES4) or Segway SNSC (1.0 or 1.1) is beeping or has a red wrench icon and flashes this code, read below.
If you clicked the wrong error code, go back to the Error Code Index.
Previous Error Code: Ninebot ESX Error Code 13 - Next Error Code: Ninebot ESX Error Code 15
Cause
It occurs when the hall sensor in the throttle receives an incorrect reading upon startup.
This can be due to demagnetization of the neodymium magnets, dislodging of the magnets, or damage to the housing of the throttle assembly causing the lever to not seat properly.
Fix
Temporary
In some cases, the error can be resolved by manually adjusting or pressing the throttle lever until the error disappears before riding.
Permanent
Magnets may be dislodged from the throttle assembly and can be re-inserted into the proper slots by taking apart the throttle assembly.
It is necessary to ensure that the polarity of the magnets is correct upon re-insertion.
In some cases, this does not fix the issue or is not the problem, to begin with.
In this case, the easiest solution is to replace the entire throttle assembly although it is possible that new magnets would also solve the issue.
If the above doesn't solve error 14, you may need to try following the steps at Replace Ninebot ESX Throttle Hall Sensor.