Ninebot ESX Error Code 15: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:


  "Brake Hall is abnormal, please check the Throttle Switch, Dashboard & related Connections"
  "Brake Hall is abnormal, please check the Throttle Switch, Dashboard & related Connections"
{{Ninebot ESX Error Code SEO|15}}


==Cause==
==Cause==
Line 8: Line 10:


This can be due to demagnetization of the neodymium magnets, dislodging of the magnets, or damage to the housing of the brake assembly causing the lever to not seat properly.
This can be due to demagnetization of the neodymium magnets, dislodging of the magnets, or damage to the housing of the brake assembly causing the lever to not seat properly.
It can also be caused if the lever is slightly pressed upon vehicle startup.


==Fix==
==Fix==
===Temporary===
In some cases, the error can be resolved by manually adjusting the brake lever until the error disappears before riding.
===Permanent===
Magnets may be dislodged from the brake assembly and can be re-inserted into the proper slots by taking apart the brake assembly. It is necessary to ensure that the polarity of the magnets is correct upon re-insertion.
In some cases, this does not fix the issue or is not the problem, to begin with. In this case, the easiest solution is to replace the entire brake assembly although it is possible that new magnets would also solve the issue.
If the above doesn't solve error 15, you may need to try following the steps at [[Replace Ninebot ESX Brake Hall Sensor]].


[[Category: Scooters]][[Category: Ninebot]][[Category: ESX]][[Category: Error Code]]