==Cause== | ==Cause== | ||
Error code 01E indicates that the current has exceeded the safe operating limit. This could be caused by: | |||
* Excessive load: The motor is being overloaded (e.g., trying to climb a steep hill, carrying too much weight). | |||
* Short circuit: There might be a short circuit in the motor windings or in the wiring connected to the motor. | |||
* Faulty controller: The motor controller (ECU) might be malfunctioning, causing it to send an excessive current to the motor. | |||
==Fix== | ==Fix== | ||
[[Category: Scooters]][[Category: | * Reduce load: If you are carrying heavy items or attempting to climb steep hills, try to reduce the load on the motor. | ||
* Check for short circuits: Inspect the motor wiring and connections for any signs of short circuits or damage. | |||
* Replace the controller: If the problem persists, the controller (ECU) might be faulty and need to be replaced. | |||
[[Category: Scooters]][[Category: Okai]] |